(Solenoid valve connector)During installation, the arrow on the valve body shall be consistent with the flow direction of the medium. Do not install it where there is direct dripping or splashing. The solenoid valve shall be installed vertically upward;
2.
(Solenoid valve connector)The solenoid valve shall ensure normal operation within the fluctuation range of 15% - 10% of the rated voltage;
3.
(Solenoid valve connector)After the solenoid valve is installed, there shall be no reverse differential pressure in the pipeline. It needs to be powered on several times to make it suitable for temperature before it can be officially put into use;
4. (Solenoid valve connector)The pipeline shall be thoroughly cleaned before the installation of solenoid valve. The medium introduced shall be free of impurities. Filter installed in front of valve;
5. When the solenoid valve fails or is cleaned, a bypass device shall be installed to ensure the continuous operation of the system.